BioCode-1000 Analyzer:
1 Sample, 1 Well, 32 or 128 Targets

BioCode-1000 Analyzer is a simple and robust BMB optical imaging system for a 96-well microplate format. After undergoing reaction, the beads settle to the bottom of each well, allowing for barcode identification and fluorescent signal detection. Multiple analyte tests can be performed in each well. One well holds one sample; therefore, each 96-well plate can simultaneously hold 96 patient samples. The system can perform 32- or 128-target test for 96 samples in one hour.

BioCode-1000 Analyzer utilizes an XY translational stage, which rapidly scans the entire microplate, as well as a CCD camera that detects both bright field barcode signal and reaction fluorescence signal. Biochemical reactions are quantitatively reported based on fluorescence intensity. Cy3 and phycoerythrin (PE) are common fluorophores used for analyte detection; other fluorophores can also be accommodated by switching optical filter sets. Through a digital barcode, each BMB microbead is encoded with the information of the biological probe immobilized on its surface. BioCode-1000 Analyzer rapidly displays the barcode and fluorescence intensity for each BMB, facilitating clear reporting of reaction results for each probe.

BioCode-1000 Analyzer Specifications

Multiplex Assays/Test 1~32 analytes, 1~128 analytes
Plate Format 96-well microplate
Bright Field Light Source LED
Fluorescence
Light Source
120W metal halide lamp
(excitation: 530nm, fluorescence: 575nm); wavelength adjustable depending on filter sets for PE, Cy3, Cy5, QD, NIR dye, etc.
Detector CCD, 12 bit; with IEEE 1394 host computer interface
Sensitivity 0.5 f mole GAPDH (DNA) or
1.0 pg/ml IL-2 (protein) with PE label  
Dynamic Range 4 logs
Speed Detection to result: 40 seconds per well
CV Between runs: typical 2~3%, <5%;
System to system: <10%
IT Connectivity Standard with serial RS232
Power Requirements 100 – 240VAC~, 50/60 Hz, 0.8A
Dimension 26”W x 15 3/4”D x 17”H
CE Certified Conforming to Laboratory Equipment Standards:
  • EN55011
  • EN61010-1
  • EN61326-1
  • IEC61010
  • EN61000-3-2
  • EN61000-3-3

Becoming Our Strategic Partners

Expand your market share by becoming Applied BioCode's partner which provides you the access to the newest multiplex platform - Barcoded Magnetic Bead technology. Please call us today 1-562-801-0050.
 

* BioCode-1000 Analyzer is intended For Research Use only. Not for use in Diagnostic Procedures.

Biocode 1000A Analyzer is robotic ready

  • No expensive lasers or complex optical alignment

  • No driving fluid & waste containers

  • No sample or bead carry-over

  • No ambiguous barcode classification

 

10020 Pioneer Blvd., Suite 102, Santa Fe Springs, CA 90670, USA, Tel: 562-801-0050, Fax: 562-801-0060